MRI
- Preventive- and corrective maintenance can be offered exclusively for SIEMENS MRI systems.
- Preventive maintenance usually is to be carried out in three months intervals and is made in accordance to the specifications of the manufacturer of the MRI – System. The appointed days of preventive maintenance usually are fixed at the beginning of each year over a time frame of 12 months.
- Corrective maintenance will be made professionally in case of a system break down. The response time of less than 2 hours can be maintained for customers in the nearer vicinity of Offenbach – for customers in the further region typically 8 hours response time can be preserved. Inmed possesses a large amount of spare parts for almost all SIEMENS MRI systems, which allows a contemporary repair of the MRI system.
- Inmed medizintechnik prepares and examines revisions and certifications through local authorities and prepares all necessary documentation.
- Inmed medizintechnik monitors the Helium Consumption, shield temperatures and water flows of all participating customers by a proprietary developed program (MaReMo Magnet Remote Monitoring) to avoid excessive Helium consumption. Inmed permanently is aware of a necessary cold head / adsorber exchange and can react immediately.
- Via MaReMo, Inmed medizintechnik has access to the Syngo user interface and can carry out all operations through a secured VNC tunnel. This sometimes can avoid unnecessary driving and waste of time.
CT
- Preventive- and corrective maintenance can be offered exclusively at SHIMADZU systems.
- Preventive maintenance usually is to be carried out in three months intervals and are made in accordance to the specifications of the manufacturer of the CT– System. The appointed days of preventive maintenance usually are fixed at the beginning of each year over a time frame of 12 months.
- Corrective maintenance will be made professionally in case of a system break down. The response time of less than 2 hours can be maintained for customers in the nearer vicinity of Offenbach – for customers in the further region typically 8 hours response time can be preserved. Inmed possesses a large amount of spare parts for all SHIMADZU CT systems, which allows a contemporary repair of the CT system.
- Constancy tests are to be carried out normally during preventive maintenance works and must be done in a 3 month interval. After a new installation, the constancy test must be made every month until the local authorities allow a quarterly interval. This is normally assured, if a quality constancy was proofed over at least one year.
- CT dose profile measurement can be accomplished every 6 months.
- Service and Installations for SIEMENS CT systems are maintained by our partner medser GmbH.
|